Specificationss
Item | Parameters |
Operating Voltage | DC 9V-16V |
Consumed Current | 0-100mA |
Support cards | Mifare one( S50, S70 etc.) |
Read Range | 0mm-100mm (related to the card or the environment) |
reader interval | <0.5S |
Format | RS232 |
Distance of transmission | RS232≥100M |
Service Temperature | -25℃ ~ +75℃ |
Size | 118mm×77mm×23mm |
Weight | About 180G |
Lead Length | 180mm±5mm |
Material | ABS & Resin adhesive (it’s waterproof) |
Status Indication | 1PC LED (Blue means standby, Green means reader success) |
Notes
1. Turn off the power and don’t live operation when installing or disassembing
2. The reader must be installed on wooden, concrete or brick wall, or placed on the table. It may not have a large area of iron and steel products within a radius of around 10 centimeters
3. Different cards has affect the distance of reader
4. If the distance of reader between two machines <0.3 m, will interfere with each other. In other words, the best distance between the reader is kept at 0.3 meters above.
5. If the card still in the sensing area, the reader without any prompts, and also don’t send data.
6. Access Control Reader cann’t store user data and information, we can’t increase the card, password and fingerprint user. It's a tool for unlocking that just expanding into the card or password , you need to rely on the access controller, attendance card machines, or multi-door controllers.
Specificationss
Item | Parameters |
Operating Voltage | DC 9V-16V |
Consumed Current | 0-100mA |
Support cards | Mifare one( S50, S70 etc.) |
Read Range | 0mm-100mm (related to the card or the environment) |
reader interval | <0.5S |
Format | RS232 |
Distance of transmission | RS232≥100M |
Service Temperature | -25℃ ~ +75℃ |
Size | 118mm×77mm×23mm |
Weight | About 180G |
Lead Length | 180mm±5mm |
Material | ABS & Resin adhesive (it’s waterproof) |
Status Indication | 1PC LED (Blue means standby, Green means reader success) |
Notes
1. Turn off the power and don’t live operation when installing or disassembing
2. The reader must be installed on wooden, concrete or brick wall, or placed on the table. It may not have a large area of iron and steel products within a radius of around 10 centimeters
3. Different cards has affect the distance of reader
4. If the distance of reader between two machines <0.3 m, will interfere with each other. In other words, the best distance between the reader is kept at 0.3 meters above.
5. If the card still in the sensing area, the reader without any prompts, and also don’t send data.
6. Access Control Reader cann’t store user data and information, we can’t increase the card, password and fingerprint user. It's a tool for unlocking that just expanding into the card or password , you need to rely on the access controller, attendance card machines, or multi-door controllers.