R301E
HECERE
Availability: | |
---|---|
Quantity: | |
Specifications
Item | Parameters |
Power Supply | DC 12V(±5%) |
Consumed Current | 45mA(standby ) 70mA(Work) |
Support Cards | TK4001\EM4100 etc. |
Operating Distance | Card:30--100mm , Keychain:30-40mm |
Reader Time | <200ms |
Format | Wiegand 26 & Wiegand 34 (Setting by yourself) |
Distance of transmission | 100M |
Service Temperature | -10℃~+60℃ |
Size | 86mm×86mm×20mm |
N.W. | About 170G |
Status Indication | 1PC LED (Red means standby, Green means reader success) |
Line definition
Colour | Parameter |
Red | VCC(12V) |
Green | Wiegand D1 |
Black | GND |
White | Wiegand D0 |
Purple | Wiegand 26/Wiegand 34 (The output format is WG34 when purple line connect with black line) |
Grey | Green light and buzzer long ring |
Notes
1. Turn off the power and don’t live operation when installing or disassembing
2. The reader must be installed on wooden, concrete or brick wall, or placed on the table. It may not have a large area of iron and steel products within a radius of around 10 centimeters
3. Different cards has affect the distance of reader
4. If the distance of reader between two machines <0.3 m, will interfere with each other. In other words, the best distance between the reader is kept at 0.3 meters above.
(Direct) (Back)
Specifications
Item | Parameters |
Power Supply | DC 12V(±5%) |
Consumed Current | 45mA(standby ) 70mA(Work) |
Support Cards | TK4001\EM4100 etc. |
Operating Distance | Card:30--100mm , Keychain:30-40mm |
Reader Time | <200ms |
Format | Wiegand 26 & Wiegand 34 (Setting by yourself) |
Distance of transmission | 100M |
Service Temperature | -10℃~+60℃ |
Size | 86mm×86mm×20mm |
N.W. | About 170G |
Status Indication | 1PC LED (Red means standby, Green means reader success) |
Line definition
Colour | Parameter |
Red | VCC(12V) |
Green | Wiegand D1 |
Black | GND |
White | Wiegand D0 |
Purple | Wiegand 26/Wiegand 34 (The output format is WG34 when purple line connect with black line) |
Grey | Green light and buzzer long ring |
Notes
1. Turn off the power and don’t live operation when installing or disassembing
2. The reader must be installed on wooden, concrete or brick wall, or placed on the table. It may not have a large area of iron and steel products within a radius of around 10 centimeters
3. Different cards has affect the distance of reader
4. If the distance of reader between two machines <0.3 m, will interfere with each other. In other words, the best distance between the reader is kept at 0.3 meters above.
(Direct) (Back)